@RobertJansen1
Copy link

Is your feature request related to a problem? Please describe.
Would it be possible to use the sensorbox to measure the current a home battery is charging / discharging to deduct from the p1 information?

Describe the solution you'd like
Add the possibility to both use p1 and ct clamps on a sensor box in order to integrate with a home battery

Describe alternatives you've considered
alternative would be to gather information and feed it through but that would depend on numerous systems translating / forwarding the data

Additional context
Add any other context or screenshots about the feature request here.

@dingo35
Copy link
Collaborator

dingo35 commented Mar 29, 2025

You are aware of the possibility to feed the battery currents via the REST and MQTT APIs?

@dingo35 dingo35 changed the title Home battery integration through sensorbox CT clamps FEATURE REQUEST: Home battery integration through sensorbox CT clamps Mar 29, 2025
@RobertJansen1
Copy link
Author

Yes i am aware but I would prefer "hardwiring" the information as that is more reliable and faster

@mstegen
Copy link
Member

mstegen commented Mar 29, 2025

What kind of battery do you have? Does it have a direct AC connection?
As the current transformers can only measure AC current, not DC.

For directly measuring DC currents going into/out a battery other (hall) current sensors are needed.
Unfortunately these are incompatible with the sensorbox, as they require an external voltage to operate.

@RobertJansen1
Copy link
Author

A zonneplan batterij with 3 phase ac

@RobertJansen1
Copy link
Author

so just ac ct clamps would work, and i also want the p1 metering to measure smart charging, but on top of that i want to exclude the battery power usage if that makes sense :) an alternative would be to substract a fixed 10kw (as it is mostly discharging with 10kw) when the delivery to the net is higher than 10kw